当前位置:首页 > 塔吊基础施工方案(最终版)
=(1410.35+42.03×1)/(446.88+6+756.25)=1.20m≤0.25b=1.38m工作状态地基承载力满足要求!
=2.75-0.85=1.90m
=(446.88+6+756.25)/(3×1.90×1.90) =111.56kN/m2 塔机非工作状态下: 当轴心荷载作用时:
=(446.88+756.25)/(5.5×5.5)=39.77kN/m2 当偏心荷载作用时:
=(446.88+756.25)/(5.5×5.5)-2×(1252.31×1.414/2)/27.73 =-24.09kN/m2
由于 Pkmin<0 所以按下式计算Pkmax:
=(1252.31+64.55×1)/(446.88+756.25)=1.09m≤0.25b=1.38m非工作状态地基承载力满足要求!
=2.75-0.77=1.98m
=(446.88+756.25)/(3×1.98×1.98) =102.69kN/m2
五. 地基基础承载力验算
修正后的地基承载力特征值为:fa=260.00kPa
轴心荷载作用:由于 fa≥Pk=39.97kPa,所以满足要求! 偏心荷载作用:由于1.2×fa≥Pkmax=111.56kPa,所以满足要求!
六. 承台配筋计算
依据《建筑地基基础设计规范》GB 50007-2011第8.2条。
1. 抗弯计算,计算公式如下:
式中 a1──截面I-I至基底边缘的距离,取 a1=0.00m; a'──截面I-I在基底的投影长度,取 a'=5.50m。 P──截面I-I处的基底反力;
工作状态下:
P=111.56×(31.90-0.00)/(3×1.90)=111.56kN/m2;
M=0.002×[(2×5.5+5.5)×(1.35×111.56+1.35×111.56-2×1.35×756.25/5.52)+(1.35×111.56-1.35×111.56)×5.5]/12 =0.00kN.m 非工作状态下:
P=102.69×(31.98-0.00)/(3×1.97617214422052)=102.69kN/m2;
M=0.002×[(2×5.5+5.5)×(1.35×102.69+1.35×102.69-2×1.35×756.25/5.52)+(1.35×102.69-1.35×102.69)×5.5]/12 =0.00kN.m
2. 配筋面积计算,公式如下:
依据《混凝土结构设计规范》GB 50010-2010
式中 α1──系数,当混凝土强度不超过C50时,α1取为1.0,当混凝土强度等级为C80时,
α1取为0.94,期间按线性内插法确定; fc──混凝土抗压强度设计值; h0──承台的计算高度。 经过计算得:
αs=0.00×106/(1.00×16.70×5.50×103×9502)=0.000 η=1-(1-2×0.000)0.5=0.000 γs=1-0.000/2=1.000
As=0.00×106/(1.000×950×360.00)=0.00mm2。 实际选用钢筋为:钢筋直径25.0mm,钢筋间距为170mm, 实际配筋面积为As0 = 3.14×252/4 × Int(5500/170)=15708mm2 实际配筋面积大于计算需要配筋面积,满足要求!
推荐参考配筋方案为:钢筋直径为25.0mm,钢筋间距为200mm,配筋面积为13499mm2
塔吊天然基础的计算书
一、计算依据
1.《建筑桩基技术规范》JGJ94-2008; 2.《混凝土结构设计规范》(GB50010-2010); 3.《建筑结构荷载规范》(GB 50009-2012); 4.《建筑地基基础设计规范》(GB50007-2011) ; 5.《上上国风东府天地勘察报告》; 6.《MC110A塔式起重机使用说明书》; 7.建筑、结构设计图纸;
8.《简明钢筋混凝土结构计算手册》。
9、依据《塔式起重机混凝土基础工程技术规程》(JGJ/T 187-2009)。
二. 参数信息
塔吊型号:波坦MC110A 起重荷载标准值:Fqk=6.00kN 塔吊计算高度:H=45m 塔机自重标准值:Fk1=446.88kN 塔吊最大起重力矩:M=843.7kN.m 塔身宽度:B=5.5m 非工作状态下塔身弯矩:M=-200.0kN.m 承台混凝土等级:C35 钢筋级别:HRBF400 承台宽度:Bc=5.50m 基础埋深:D=0m 计算简图:
地基承载力特征值:220kPa 承台厚度:h=1.35m
三. 荷载计算
共分享92篇相关文档