当前位置:首页 > Brocade SAN Switch日常维护手册
Brocade SAN Switch 日常维护手册
5)确认交换机已经完成POST
6)当超级终端停止报告信息,按“Enter” 显示login信息,login 7) 默认用户:admin,默认密码:password。
2.1.2 网络管理口连接登陆
用telnet工具通过Brocade 光纤交换机 IP地址登陆。默认用户:admin,默认密码:password。
2.2 Brocade设备日常巡检命令 2.2.1 Uptime
显示交换机工作时间 检查该交换机当前时钟,目前有几个用户登录到这台交换机,以及它已经正常工作了多长时间等信息。 switch:admin> uptime
12:03am up 4:56, 3 users, load average: 1.17, 1.08, 1.08
2.2.2 Ipaddrshow
显示交换机IP地址信息 switch:admin> ipaddrshow SWITCH
Ethernet IP Address: 192.168.163.238 Ethernet Subnetmask: 255.255.255.0 Gateway IP Address: 192.168.163.1 DHCP: Off
IPv6 Autoconfiguration Enabled: No Local IPv6 Addresses:
static 1080::8:800:200c:417a/64
第 9 页 共 21 页
Brocade SAN Switch 日常维护手册
2.2.3 Licenseshow
显示当前交换机所添加的license信息 licenseshow:
cedbR9SRydfecSv: Web license ReQebdQeS9SfRfcr: Zoning license SdSddRczSSTeTeeb: Fabric license
2.2.4 Switchshow
检查交换机信息及端口状态 switch:admin> switchshow switchName: sw0 switchType: 66.1 switchState: Online switchMode: Native switchRole: Subordinate switchDomain: 2 switchId: fffc02
switchWwn: 10:00:00:05:1e:57:b3:06 zoning: OFF switchBeacon: OFF FC Router: ON
FC Router BB Fabric ID: 128
Index Port Address Media Speed State Proto
============================================== 0 0 020000 id N4 No_Light FC
1 1 020100 id N4 In_Sync FC Disabled 2 2 020200 id N4 No_Light FC 3 3 020300 id N4 No_Light FC
2.2.5 Switchstatusshow
显示交换机运行状态
重点检查如果交换机状态为healthy,则表示交换机当前运行正常,如果有不是healthy的状态出现,则需要根据具体问题使用相关命令继续检查。 switch:user> switchstatusshow
Switch Health Report Report time: 09/11/2006 05:39:28 PM Switch Name: switch
第 10 页 共 21 页
Brocade SAN Switch 日常维护手册
IP address: 1080::8:800:200C:417A SwitchState: MARGINAL Duration: 80:12
Power supplies monitor HEALTHY Temperatures monitor HEALTHY Fans monitor HEALTHY Flash monitor MARGINAL Marginal ports monitor HEALTHY Faulty ports monitor HEALTHY Missing SFPs monitor HEALTHY
All ports are healthy
2.2.6 Firmwareshow
显示微码版本信息
检查交换机当前微码是否符合微码评估要求,是否存在Bug,是否需要升级 firmwareshow:
Slot Name Appl Primary/Secondary Versions Status ------------------------------------------------------------------------
5 CP0 FOS v5.3.0c STANDBY
v5.3.0c
6 CP1 FOS v5.3.0c ACTIVE *
v5.3.0c
2.2.7 Fanshow
显示风扇运行状态
重点检查当前交换机散热风扇状态是否为OK fanshow:
Fan 1 is Ok, speed is 2020 RPM Fan 2 is Ok, speed is 1985 RPM Fan 3 is Ok, speed is 1985 RPM
2.2.8 Tempshow
显示交换机当前温度信息
检查当前交换机的温度传感器是否为OK状态 tempshow:
第 11 页 共 21 页
Brocade SAN Switch 日常维护手册
Sensor Slot State Centigrade Fahrenheit ID
===================================================== 1 1 Absent 2 2 Absent
3 3 Ok 31 87 4 4 Ok 31 87 5 5 Ok 31 87 6 6 Ok 32 89 7 7 Ok 32 89 8 8 Absent 9 9 Absent 10 10 Absent
2.2.9 Psshow
显示电源运行状态:
电源状态都是OK则表明电源运行正常,absent表示没有插电源。 psshow:
Power Supply #1 is OK
DELTA DPS1001AB-1EM 23020000603 01 FL2L9025586 Power Supply #2 is OK
DELTA DPS1001AB-1EM 23020000603 01 FL2L9025567 Power Supply #3 is absent Power Supply #4 is absent
2.2.10 Slotshow
显示板卡运行状态
如果板卡状态为ENABLE,则表示此槽位板卡正常
如果板卡状态为VACANT,板卡类型为UNKNOWN,则需要根据具体配置情况检查该槽位是否真的没有插卡,如确实没有插卡,则此状态正常。 slotshow:
Slot Blade Type ID Status ---------------------------------
1 UNKNOWN VACANT 2 UNKNOWN VACANT 3 SW BLADE 36 ENABLED 4 SW BLADE 36 ENABLED 5 CP BLADE 16 ENABLED 6 CP BLADE 16 ENABLED 7 SW BLADE 36 ENABLED
第 12 页 共 21 页
共分享92篇相关文档