当前位置:首页 > 整体式钢筋混凝土简支板桥设计计算书
12Icr?bx3??EsAs?h0?x?312??1000?83.023?7.143?2513??275?83.02? 3?190733479.87?661584182.6?8.523?108mm4(4) 开裂截面抗弯刚度
Bcr?EcIcr?2.8?104?8.523?108?2.3864?1013N?mm2
2)全截面换算截面的截面特性
(1) 全截面换算截面面积
A0?bh??Es?1As?1000?320??7.143?1??2513 ?335437.36mm2(2) 全截面换算截面受压区高度
12bh??Es?1Ash0x?2A0????1?1000?3202??7.143?1??2513?275 ?2335437.3651200000?4245273.725?335437.36?165.29mm(3) 全截面换算截面惯性矩
12?1?I0?bh3?bh?h?x???Es?1As?h0?x?12?2?2??1?1???1000?3203?1000?320???320?165.29?12?2? ??7.143?1??2513??275?165.29??2.925?109mm4(4) 全截面换算截面受拉区边缘的弹性抵抗矩
22
?2730666666.7?8954912?185808438.7I02.925?109W0???1.89?107mm3
h?x320?165.29(5) 全截面换算截面的面积矩
11S0?bx2??1000?165.292?1.366?107mm3
22(6) 全截面抗弯刚度
B0?0.95EcI0?0.95?2.8?104?2.925?109?7.78?1013N?mm2 (7) 塑性影响系数
2S02?1.366?107????1.4455 7W01.89?103)开裂弯矩
Mcr??ftkW0?1.4455?1.78?1.89?107?4.863?107N?mm=48.63KN?m 4)开裂构件的抗弯刚度
B?B022?Mcr???Mcr??B0????1????MB?Msd????sd???cr7.78?1013? 2213??7.78?10?48.63??48.63??1???????1387.822.3864?10?87.82????????3.03?1013N?mm25)挠度长期增长系数
本桥采用的混凝土为C25,故?θ?1.65 6)构件在使用阶段的跨中截面的长期挠度值
5Msdl2?l????θ48B5?48?16.13mm?87.82?106??5.69?103?3.03?10132?1.65
7)构件在结构自重作用下跨中截面的长期挠度值
5MGl2?G????θ48B587.8240.75?10??5.69?10??483.03?1013?7.484mm632??1.65
8)按可变作用频遇值计算的长期挠度值
?l?5.69?103?Q??l??G?16.13?7.484?8.646mm?9.483mm??
600?600?满足要求 9)预拱度设值
?l?5.69?103?l?16.13mm>??3.556mm??,故跨中截面不设预拱度。 1600?1600?(四) 短暂状况构件应力验算
本桥为现场整体浇筑,无需进行短暂状况构件应力验算。
七、 分布钢筋构造布置
构造要求:
1、 直径不小于8mm; 2、 间距不应大于200mm;
3、 截面面积不宜小于板截面面积的0.1%; 4、 在所有主钢筋的弯折处均应设置。 对于本桥,分布钢筋的具体布置见钢筋构造图。
附件:图纸 需进一步的工作: 1、 图的绘制;
2、 图形的绘制
1) 一般构造图 2) 钢筋图