当前位置:首页 > Phoenix-Award BIOS v02.63 设置 中文说明书
口选择(FDC Floppy Dsk Controller);该项均为开启状态,否则无法 控制软盘驱动器. 可用选项:Enabled(默认值),Dsabled. Serial Port1 Address(串行端口1功能) 此项用于设置内建串行端口 COM1的中断及I/O地址设置. 可用选项:Dsabled,3F8/IRQ4,2F8/IRQ,3E8/IRQ4,2E8/IRQ3,Auto.
- 21 -
UNIKA UR785GT主板中文手册
3.1.6 Power Management Features(电源管理)
电源管理设置可设置计算机电源管理功能,有效减低个人计算机系统电源消
耗.若要完全发挥管 理功能,则需正确设置选择,加上硬件外设配合.
Phoenix – Award Workstation BIOSCMOS Setup Utility Power Management
Features Power Management Features Help Item Power Management/APM Enabled Enabled/Disable SMI Suspend Time Out Disabled based power management Power Button Mode On/Off and APM support. Video Power Down Mode Suspend Hard Disk Power Down Mode Suspend Hard Disk Time Out (Minute) Disabled RTC Alarm Resume Disabled
↑↓→←:Move Enter: Select F5:Previous Values
+/-/:Value F10:Save ESC:Exit F1:General Help F6: Optimized Defaults
F7:Standard Defaults
Power Management Option(电源管理功能选择) 此选单用于选择省电类型
(或程度),且和下列模式有直接的关连: 可用选项:Mn. Savng, Max. Savng, User Defined(默认值). RTC Alarm Resume(定时开机设置) 该项设置系统定时开机,可设定每月某一天某一时刻或每天某一时刻开机. 可用选项:Enabled,Dsabled(默认值). x
Date of Month Alarm(日期设定) 您可设定每月定时开机的日期. x Time(hh:mm:ss) Alarm(时间设定) 您可设定每天定时机的时间.
- 22 -
UNIKA UR785GT主板中文手册 3.1.7 Miscellaneous Control(特殊控制)
Phoenix – Award Workstation BIOSCMOS Setup Utility Miscellaneous Control
Advanced PCI/Pnp Settings Help Item Clear NVRAM Clear NVRAM during Plug & PLay O/S System Boot. PCI Latency Timer Allocate IRQ to PCI VGA Palette Snooping PCI IDE BusMaster OffBoard PCI/ISA IDE Card IRQ Resouces
▲
↑↓→←:Move Enter: Select F5:Previous Values
+/-/:Value F10:Save ESC:Exit F1:General Help F6: Optimized Defaults
F7:Standard Defaults
PCI/VGA Palette Snoop(VGA监控) 此项用于监控VGA调色盘的状态,在使
用早期的一些视频卡时,会发生颜色偏差或异常反白的情 形,此时就必须成Enabled,以改善这种现象.现在已经很少使用,请维持Dsabled默认值设置. 可用选项:Enabled,Dsabled(默认值). Maximum Payload Size(PCI Express总线净载荷尺寸) 该项可以设置PCI Express总线的净载荷尺寸,建议保留默认值. 可用选项:128,256,512,1024,2048,4096. x IRQ Resources(系统IRQ资源控制) 当希望对系统\资源\进行控制时,此项可按键进入附加菜单进行IRQ的具体设置.IRQ9/IRQ-10/IRQ-11/IRQ-14/IRQ-15 assgned to(中断资源保留)该项可以选择某一个中断号(IRQ)指定给 PCI设备使用或者是在系统资源中保留. 可用选项:PCI
Devce(默认值),Reserved.
Phoenix – Award Workstation BIOSCMOS Setup Utility IRQ Resources
assigned to PCI Device Help Item assigned to PCI Device assigned to PCI Device assigned to PCI Device assigned to PCI Device
IRQ-9 IRQ-10 IRQ-11 IRQ-14 IRQ-15 ↑↓→←:Move Enter: Select F5:Previous Values
+/-/:Value F10:Save ESC:Exit F1:General Help F6: Optimized Defaults
F7:Standard Defaults
- 23 -
UNIKA UR785GT主板中文手册 3.1.8 PC Health Status(PC状态监控)
Phoenix – Award Workstation BIOSCMOS Setup Utility PC Health Status PC
Health Status Help Item Smart FAN Configurations Press Enter H/W Health Function CPU Temperature SYS Temperature CPUFAN Speed SYSFAN1 Speed SYSFAN2 Speed NB1.2V VDIMM VCORE NBPCIE Enabled 45℃/113℉ 39℃/102℉ 2782 RPM N/A N/A 1.152V 1.512V 1.352V 1.120V
↑↓→←:Move Enter: Select F5:Previous Values
> Smart FAN Configurations 当希望对系统\FAN Configurations\进行
风扇智能控制时,此项可按键进 入附加菜单进行具体设置.
Phoenix – Award Workstation BIOSCMOS Setup Utility Smart FAN
Configurations CPUFAN Smart Mode Disabled Item Help x CPU SmartFAN Full-speed Temp 50℃ x CPU SmartFan idel Temp 30℃ Menu Level
↑↓→←:Move Enter: Select F5:Previous Values
CPUFAN Full-Speed Temp(系统风扇1全速工作温度) 该项可以设定系统风
扇1全速运行的温度临界值,当系统侦测到系统温度高于设置的临界 值时,将会控制系统风扇1全速运转. 可设置选项:30℃-100℃. CPUFAN Idel Temp(系统风扇1空闲温度) 该项可以设定系统风扇1降速运行的温度临界值,当系统侦测到系统温度低于设置的临界 值时,将会控制系统风扇1降速运行. 可设置选项:30℃-100℃. Show H/W Health in POST(开机自检设置) 该项为设置开机自检时是否显示PC状况. 可用选项: Enabled,Dsabled.
▲
+/-/:Value F10:Save ESC:Exit F1:General Help F6: Optimized Defaults
F7:Standard Defaults
+/-/PU/PD:Value F10:Save ESC:Exit F1:General Help F6: Fail-Safe Defaults F7:
Optimized Defaults
▲ - 24 -
UNIKA UR785GT主板中文手册
Vcore NB1.25V 5VSB +12 +5 VDIMM CPU Temperature System Temperature
CPUFan Speed SYSFAN1 SYSFAN2 CPU电压 北桥电压 主板5VSB电压 主板+12V电压 主板+5V电压 内存电压 CPU温度 系统温度 CPU风扇转速 系统风扇1转速 系统风扇2转速
3.1.9 Thermal Throttling Options(热量控制)
Phoenix – Award Workstation BIOSCMOS Setup Utility CPU Thermal
共分享92篇相关文档