??1C?s???K?1??sTd??s?Ti???1?sTdN?12 (3.2)

This structure has the advantage that we can develop the design methods for an ideal PID controller and use an iterative design procedure. The controller is first designed for the process P(s). The design gives the controller parameter Td. An ideal controller for the process P(s)/(1+sTd/N)2 is then designed giving a new value of Td etc. Such a procedure will also give a clear picture of the tradeoff between performance and filtering. Set Point Weighting

When using the control law given by (2.1) it follows that a step change in the reference signal will result in an impulse in the control signal. This is often highly undesirable there for derivative action is frequently not applied to the reference signal. This problem can be avoided by filtering the reference value before feeding it to the controller. Another possibility is to let proportional action act only on part of the reference signal. This is called set point weighting. A PID controller given by (2.1) then becomes

t?1?dr?t?dy?t????u?t??Kbr?t??y?t??e???d??Td?c? (3.3) ?????dtdt???Ti0?Where b and c are additional parameter. The integral term must be based on error feedback to ensure the desired steady state. The controller given by D6.4E has a structure with two degrees of freedom because the signal path from y to u is different from that from r to u. The transfer function from r to u is

??U?s?1?cr?s??K?b??csTd? (3.4)

??R?s?sTi??

45

Time t

Figure 3.1 Response to a step in the reference for systems with different set point weights b= 0 dashed, b = 0?5 full and b=1?0 dash dotted. The process has the transfer function P(s)=1/(s+1)3 and the controller parameters are k = 3, ki = 1?5 and kd = 1?5. and the transfer function from y to u is

??U?s?1?cy?s??K?1??sTd? (3.5)

?s?R?s?Ti??Set point weighting is thus a special case of controllers having two degrees of freedom. The system obtained with the controller (3.4) respond to load disturbances and measurement noise in the same way as the controller (2.1) . The response to reference values can be modified by the parameters b and c. This is illustrated in Figure 6.4, which shows the response of a PID controller to set-point changes, load disturbances, and measurement errors for different values of b. The figure shows clearly the effect of changing b. The overshoot for set-point changes is smallest for b = 0, which is the case where the reference is only introduced in the integral term, and increases with increasing b.

The parameter c is normally zero to avoid large transients in the control signal due to sudden changes in the set-point. 4 Different Parameterizations

The PID algorithm given by Equation(2.1)can be represented by the transfer function

??1?G?s??K1??sTd? (4.1) ?s?Ti??

46

  • 收藏
  • 违规举报
  • 版权认领
下载文档10.00 元 加入VIP免费下载
推荐下载
本文作者:...

共分享92篇相关文档

文档简介:

??1C?s???K?1??sTd??s?Ti???1?sTdN?12 (3.2) This structure has the advantage that we can develop the design methods for an ideal PID controller and use an iterative design procedure. The controller is first designed for the process P(s). The design gives the controller parameter Td. An ideal controller for the process P(s)/(1+sTd/N)2 is then designed giving a new value of T

× 游客快捷下载通道(下载后可以自由复制和排版)
单篇付费下载
限时特价:10 元/份 原价:20元
VIP包月下载
特价:29 元/月 原价:99元
低至 0.3 元/份 每月下载150
全站内容免费自由复制
VIP包月下载
特价:29 元/月 原价:99元
低至 0.3 元/份 每月下载150
全站内容免费自由复制
注:下载文档有可能“只有目录或者内容不全”等情况,请下载之前注意辨别,如果您已付费且无法下载或内容有问题,请联系我们协助你处理。
微信:fanwen365 QQ:370150219
Copyright © 云题海 All Rights Reserved. 苏ICP备16052595号-3 网站地图 客服QQ:370150219 邮箱:370150219@qq.com