Page 1 of 8
GF3.1 Engineer Lab Engineer Requested Date Re-test Full-test Modification Construction check Add Test after review
Laboratory Measurements
Client Appliance Model No. Sample No. Standard Report No. SAP No. + Item
Foxlink AC Adapter FA-T1202500SA
Total Pages: 16
IEC/EN 60950-1:2001
(If no tick, put into default tray)
Lab Measurements return to Engineer directly
Lab Use Only Lab Start Date Remarks: / /2008
/ /2008 Lab target Date Unless otherwise specified, all values mentioned in this lab report are in r.m.s. value Rating of the equipment: Input: AC 100-240V; 50/60Hz; 0.8A; Class I Output: 12VDC, 2.5A Ambient temperature:
Mass weight: __0.26_Kg * Clause(s) Test(s) 1.6.2 Input Current Test 1.7.13 Durability of Marking Test 2.1.1.5 Energy Hazard in Operator Access Area 2.1.1.7 Discharge of Capacitors 2.2.2 SELV limits for Normal Conditions 2.2.3 SELV limits for Abnormal Conditions 2.4.2 Limited Current Circuits 2.5 Limited Power Sources 2.6.3.4 Resistance of Earthing Circuit 2.9.2 Humidity Conditioning 2.10.2 Working Voltage over Insulation 4.1 Stability Test (10 Tilting Test) 4.2.4 Steady Force Test, 250N 4.2.5 Impact Test (Steel Ball) 4.2.6 Drop Test 4.2.7 Stress Relief Test 4.3.6 Torque Test (direct-plug in) 4.5.1 Maximum Temperature Test 4.5.2 Ball Pressure Test 5.1.6 Touch Current and Protective conductor current 5.2 Electric Strength Test 5.3 Fault Condition Test * Select the test(s) to be done.
Result P P P P P P P P / F P P P P / F P P P / F P P P P / F P P P / F Equipment used Remark Remark: Please submit the test plan together with the tables for clause 2.2.3, 2.5, 4.5.1, 4.5.2, 5.2 and 5.3
Attachments:
....................................... Date Signature
.......................................
Date Signature
.......................................
Date Signature
This template is designed for quick reference. This is not a guideline for selection of tests and test conditions. Template prepared by: Clarice Chen Date: 20/03/2006
Page 2 of 8
Test Engineer
Check by
Approved by
1.6.2 fuse # TABLE: electrical data (in normal conditions) Irated (A) U/F (V/Hz) P (W) I (mA) Ifuse (mA) condition/status P Model: FA-T1202500SA F1 F1 F1 F1 F1 F1 F1 F1 Note: Pass: <10% of Rated current under any Rated Voltage/Range. 1.7.13 Durability of Marking The label was rubbed with cloth soaked with water for 15 s and again for 15 s with the cloth soaked with petroleum spirit. Curling? Yes / No Legibility? Yes / No 2.1.1.5 TABLE: max. V, A, VA test Current (rated) (A) Voltage (max.) (V) Current (max.) (A) VA (max.) (VA) P P -- 0.8 0.8 -- -- 0.8 0.8 -- 90V/50Hz 100V/50Hz 240V/50Hz 264V/50Hz 90V /60Hz 100V/60Hz 240V/60Hz 264V/60Hz 36.9 36.5 36.3 36.5 36.9 36.8 36.5 36.8 655 592 279 257 657 587 322 290 655 592 279 257 657 587 322 290 Loaded with 12.0V/2.5A See above See above See above See above See above See above See above Voltage (rated) (V) Model: FA-T1202500SA 12.0 Note: 2.5 12.11 3.53 40.12 Under highest rated voltage 264V/60Hz 2.1.1.7 Condition At input plug pin TABLE: discharge test P (ms) 424 (s) ? calculated ? measured t u? 0V Comments (ms) 440 2.073 Plug pin measured: __364__Vpeak, 37%Vpeak= __134.68V_
Remarks:
Page 3 of 8
Note(s): Supply voltage: 264V/60Hz Overall capacity: uF (CX1= 0.22 uF) Discharge resistor: 2M ohm(R1=R2=1M ohm) Pass: time constant <1s, if C<=0.1μ no test required Under +10% or +6% of the highest Rated Voltage. Test was repeated with all switches in all possible positions. 2.2.2 TABLE: Hazardous voltage measurement Location max. Voltage V peak Model: FA-T1202500SA TR1 transformer Note: Under highest Rated Voltage: 264V/60Hz Measured at the output of safety isolation transformer and component used in series with transformer till SELV voltage measured. 2.2.3 Location Model: FA-T1202500SA Output terminal Note: Under highest Rated Voltage. Measured on user accessible connector or connector to other equipment under both normal condition and fault condition (short components before SELV in 2.2.2, open circuit voltage sensing circuit, etc) 2.4.2 Location Y1 capacitor Note: Under highest Rated Voltage. Measured under both normal condition and fault condition. A 2000 ohm non-inductive resistor used when testing 2.5 TABLE: limited power source measurement P TABLE: limited current circuit measurement Voltage (V) 8.4 Current (mA) 4.2 Freq. (kHz) 60 Limit (mA) 42 Comments 240V/60Hz supplied P 0(Unit shut down) Diode D4 short TABLE: SELV voltage measurement Voltage measured (V) Comments P Pin 8 to 9 C8 65.0 -- -- 12.1 After diode D4 V d.c. Voltage Limitation Component P Transformer - The output is limited to the limits of table 8 under normal and single fault condition. Model: FA-T1202500SA Uoc = 12.11 V (measured under no load conditions)
Remarks:
Page 4 of 8
Limits Measured Verdict According to Table 2B with the max. load conditions current (in A) power (in VA) Isc x Uoc <250VA Isc: 3.53 S: 40.12 According to Table 2B/2C : Under the U3 primary short condition current (in A) power (in VA) Isc x Uoc <250VA Isc: 0(Unit shut down) S: 0(Unit shut down) According to Table 2B/2C: Under the U3 secondary short condition current (in A) power (in VA) Isc x Uoc <250VA Isc: 0(Unit shut down) S: 0(Unit shut down) According to Table 2B/2C: Under the U3 primary open condition current (in A) power (in VA) Isc x Uoc <250VA Isc: 0(Unit shut down) S: 0(Unit shut down) According to Table 2B/2C: Under the U3 secondary open condition current (in A) power (in VA) Isc x Uoc <250VA Isc: 0(Unit shut down) S: 0(Unit shut down) According to Table 2B/2C : Under the U2 primary short condition current (in A) power (in VA) Isc x Uoc <250VA Isc: 0(Unit shut down) S: 0(Unit shut down) According to Table 2B/2C: Under the U2 secondary short condition current (in A) power (in VA) Isc x Uoc <250VA Isc: 3.38 S: 39.2 According to Table 2B/2C: Under the U2 primary open condition current (in A) power (in VA) Isc x Uoc <250VA Isc: 3.39 S: 39.5 According to Table 2B/2C: Under the U2 secondary open condition current (in A) power (in VA) Isc x Uoc <250VA Isc: 3.39 S: 39.5 According to Table 2B/2C: Under the R3 short condition current (in A) power (in VA) Note: Disable the power protection circuit for abnormal conditions. Under highest Rated Voltage.
Isc x Uoc <250VA Isc: 5.41(Fuse open,BG1.Q1damaged) S: 57.2(Fuse open,BG1.Q1damaged)
Remarks: