当前位置:首页 > 石油大学华东油气储运本科毕设-输油管道初步设计
第2章 工艺计算书
同理得:Tpj?43.187℃
??pj?39.99cp
?pj?885?(1.825-0.001315?885)?43.187?869.67kg/m3
115.74?0.13308m3/s
869.6739.99?10?3?pj??45.98?10?6m2/s
869.671.750.13308?(45.98?10?6)0.25?i?0.0246??0.005165
0.39064.75Qmin?a?1.218?10?5
115.74?9.8?0.005165b??1.978℃
2.2432???0.4204?TR??T0?b???TZ?T0?b?eaLR?(1?1.978)?(33?1?1.978)e同理得:Tpj?42.547℃
1.218?10?5?55?103
?61.64km??pj?40.82?10?3Pa·s
?pj?885?(1.825-0.001315?885)??42.547?20??870.09kg/m3
115.74?0.13302m3/s
870.0940.82?10?3?pj??46.91?10?6m2/s
870.091.750.13302?(46.91?10?6)0.25?i?0.0246??0.005187 4.750.3906Qmin?2.4.2 热力、水力校核 (1)热力校核
已知:Qmax?0.19019m3/h?684.68m3/h Gmax?165.34
a?8.528?10?6 L=55km
设 :TZ?33℃ 初取b=5.411℃ TR??T0?b???TZ?T0?b?eaLR
?(1?5.411)?(33?1?5.411)e8.528?10同理得:Tpj?38.304℃
- 30 -
?6?55?103?48.91℃
第2章 工艺计算书
i=0.009955
165.34?9.8?0.009955b??5.447℃
2.2432???0.4204?TR??T0?b???TZ?T0?b?eaLR
?(1?5.447)?(33?1?5.447)e8.528?10?6?55?103?48.89km
? 满足热力要求,b值与假设相近,计算符合要求。
同理在最小输量下计算得:满足热力要求,b值与假设相近,计算符合要
(2)水力校核 管道承压: H承压?P?g?6.86MPa869.35?9.8?805.20m
①最大输量下八个热泵站全开,只能对泵站进行拆级使用。 设首站进站压力Hs1?50m
首~2#
?Hd?H泵?Hs1?567.72?50?617.72m?55?103?(33?18)?30?592.525m [H]?iLR??Z?hm?0.009955?H剩?25.195m八级泵
2#~3#
?Hd?H泵?Hs1?567.72?25.195?592.915m[H]?iLR??Z?hm?0.009955?55?103?10?30?567.525m?H剩?25.39m
八级泵
3#~4#
?Hd?H泵?Hs1?638.69?25.39?664.08m[H]?iLR??Z?hm?0.009955?55?103?10?30?587.525m?H剩?76.555m
九级泵
4#~5#
- 31 -
第2章 工艺计算书
?Hd?H泵?Hs1?567.72?76.555?644.275m[H]?iLR??Z?hm?0.009955?55?103?9?30?568.525m?H剩?75.75m
八级泵
5#~6#
?Hd?H泵?Hs1?567.72?75.75?643.47m[H]?iLR??Z?hm?0.009955?55?103?8?30?585.525m
?H剩?57.9456#~7#
?Hd?H泵?Hs1?567.72?57.945?625.665m[H]?iL3R??Z?hm?0.009955?55?10?14?30?591.52m?H剩?34.14m7#~8#
?Hd?H泵?Hs1?567.72?34.14?601.86m[H]?iLR??Z?hm?0.009955?55?103?6?30?571.525m?H剩?30.335m8#~末站
?Hd?H泵?Hs1?567.72?30.335?598.055m[H]?iLR??Z?hm?0.009955?55?103?22?30?55.525m?H剩?42.53出站压力经校核满足要求。
②最小输量下开四个热泵站四个热站 首~3#
?Hd?H泵?Hs1?631.35?50?681.35m[H]?iLR??Z?hm?0.005187?110?103?5?30?605.57m ?H剩?Hd?[H]?75.78m3#~5#
- 32 -
八级泵
八级泵
八级泵
八级泵
九级泵
第2章 工艺计算书
?Hd?H泵?Hs1?561.2?75.78?636.98m[H]?iLR??Z?hm?0.005187?110?103?1?30?601.57m ?H剩?35.41m 八级泵
5#~7#
?Hd?H泵?Hs1?631?35.41?666.41m[H]?iLR??Z?hm?0.005187?110?103?22?30?622.57m ?H剩?43.84m7#~末站
?Hd?H泵?Hs1?561.2?43.84?605.4m[H]?iLR??Z?hm?0.005187?110?103?28?30?572.57m ?H剩?32.47m出站压力经校核满足要求。
2.5 反输计算
2.5.1 反输量确定
在建设初期投产运行之前要进行反输计算,以最小输量计算。其中: 取TR?61.63℃;Tz=33℃。
由GK?DlRmin? clT?T 得:
Rmax0nTzmin?T02.2432?3.14?0.4064?55?103Gm??118.71kg/s>70%2.1?ln62.87?1Gmax
33?1=Gmin=115.74kg/s
所以反输量G=Gmin=115.74kg/s
2.5.2 翻越点判断
T13.63?2pj??613?33?42.543 ℃
?42.543?885?0.661225?22.543?870.094kg/m3
- 33 -
九级泵
八级泵
共分享92篇相关文档