当前位置:首页 > 焊接结构试题及参考答案
288(C) A groove weld qualification on 1/2 in. plate qualifies a procedure for what range of thicknesses ? (在1/2 英寸板材上进行的坡口焊接工艺评定覆盖的板材厚度范围?) a. 0 to 1 in. b. 0 to 3/4 in. c. 1/8 in. to 1 in. d. 1/8 in. to 3/4 in.
e. None of the above (以上都不对)
289 (A) How many times may low hydrogen electrodes be rebaked ? (低氢焊条最多可以重新烘干几 次?)
a. Once (一次) b. Twice (两次)
c. Not limited (没有限制)
d. Not limited , except if coating is damaged (除非药皮被破坏了) e. Not specified (没有要求)
290 (C) What is the allowable deviation from straightness for a 40 foot long primary truss member ? (对40 英寸长的主珩架构件允许的直线度偏差是多少?) a. 1/2 in. b. 7/16 in. c. 3/8 in. d. 5/16 in. e. 1/4 in.
291 (E) What is the allowable variation between the center lines of the web and flange of a 30 feet long built-up I-bean ? (30 英寸长的组装工字梁的腹板中心线和翼板中心线间的允许变化值是多少?) a. 1/2 in. b. 7/16 in. c. 3/8 in. d. 5/16 in. e. 1/4 in.
292 (B) What is allowable misalignment between members of a butt joint, under any circumstances ? (在任何情况下,对接焊缝的错边允许多少?) a. No misalignment permitted (不允许错边) b. 1/8 in.
c. 10% of the thickness of the thinner member (较薄件厚度的10%) AWS D1.1 Code Clinic Exercise Questions
d. 10% of the thickness of the thicker member (较薄件厚度的10%) e. 3/16 in.
293 (A) What maximum depth of undercut is permitted in transverse splices of primary members ? (在主 要构件中,横向接缝的咬边最大允许多深?) a. 0.01 in.
49
b. 1/32 in. c. 1/16 in.
d. None permitted (不允许) e. Not specified (没有要求)
294 (E) In what circumstances, if any, can a CWI whose certification has-expired, accept D1.1 work ? (在 什么情况下一个证书已经过期的CWI 可以接受按照D1.1 做的工作?) a. Not permitted due to expiry of certification (不允许,因为证书已过期) b. Requires engineer approval (需要工程师批准)
c. Permitted with a current visual acuity test (需要视觉灵敏度测试)
d. Permitted with current visual acuity test and engineer approval (需要视觉灵敏度测试和工 程师批准)
e. May only work as a CAWI (只能作为助理焊接检验员工作)
295 (C) What action is required if a crack 1/4 in. long is observed in a standard 5/8 in. stud head ? (如果 5/8 英寸的螺柱头部发现一条1/4 英寸长的裂纹,则采取什么行动:) a. No action, use as is (照常使用)
b. Repair crack and use (修复裂纹后使用)
c. Do not use , replace stud (不能使用,替换螺柱)
d. Suitable only for concrete encased studs (只能用做水泥包住的螺柱) e. Notify stud manufacturer (通知螺柱制造商)
3. 填空题
1.材料如果不按扎制方向进行下料切割将使强度降低 30% ,延伸率降低 50% 。 2. 当采用SMAW焊接时风速大于 16千米/小时,需要采取必要的防风措施。
3. 当采用GTAW和FCAW焊接时风速大于 8千米/小时,的时需要采取必要的防风措施。 4.在动循环载荷情况下对接焊缝和非管连接的角焊缝的咬边不能超过 0.25 毫米.。 5.静载荷情况下对接焊缝和非管连接的角焊缝的咬边不能超过 1 毫米。 6.焊角尺寸小于等于8毫米的凸值为 1.6 毫米。 7.焊角尺寸大于8毫米小于25毫米的凸值为 3 mm。 8.焊角尺寸大于25毫米的凸值为 5 mm。
9. 两面角50°至135°焊缝金属为壁厚的 1.25 倍 。 10.两面角35°至50°焊缝金属为壁厚的 1.5 倍。 11.两面角小于35°焊缝金属为壁厚的 1.75 倍 。 12.两面角小于30°焊缝金属为壁厚的 2 倍 .
13..当不同厚度杆件拼接时,如厚度差超过较薄杆件厚度的25%或超过3毫米时,应通过对较厚杆件部分斜切,
使厚度偏差的两个表面或边缘有光滑的锥型过渡,该过渡的长度不能小于厚度偏差的 2.5 倍。
14.任何返修的最小长度为50.8mm.用点焊返修针状气孔或其他缺陷是不可以的.即使缺陷不大,返修的长度至少为50.8mm.
15.无损检验确定缺陷大小后,在任何情况下在缺陷的任何一端外的 25mm 无缺陷金属都要去掉,针孔状气孔缺陷或其他缺陷不允许用点焊进行返修。
16.低碳钢的最低屈服强度小于等于280MPa(40ksi),碳当量一般小于或等于0.40%。此类钢适用于AWS D1.1
50