云题海 - 专业文章范例文档资料分享平台

当前位置:首页 > 金风1500kW风机常见故障处理手册

金风1500kW风机常见故障处理手册

  • 62 次阅读
  • 3 次下载
  • 2025/5/3 6:14:22

42.1故障描述 ....................................................................... 42 40.2故障原因 ....................................................................... 42 42.3故障处理 ....................................................................... 42 43变桨安全链 ............................................................................ 43

43.1故障描述 ....................................................................... 43 43.2故障原因 ....................................................................... 43 43.3故障处理 ....................................................................... 44 44发电机过速1 ......................................................................... 47

44.1故障描述 ....................................................................... 47 44.2故障原因 ....................................................................... 47 44.3故障处理 ....................................................................... 47 45发电机转速比较故障 .............................................................. 47

45.1故障描述 ....................................................................... 47 45.2故障原因 ....................................................................... 48 45.3故障处理 ....................................................................... 48 46振动开关 ............................................................................... 48

46.1故障描述 ....................................................................... 48 46.2故障原因 ....................................................................... 48 46.3故障处理 ....................................................................... 49 47环境温度高故障 ..................................................................... 49

47.1故障描述 ....................................................................... 49

13 / 53

47.2故障原因 ....................................................................... 49 47.3故障处理 ....................................................................... 49 48水冷系统加热故障 ................................................................. 50

48.1故障描述 ....................................................................... 50 48.2故障原因 ....................................................................... 50 48.3故障处理 ....................................................................... 50 49水冷系统流量低故障 .............................................................. 50

49.1故障描述 ....................................................................... 50 49.2故障原因 ....................................................................... 50 49.3故障处理 ....................................................................... 50 50变流器未调制故障 ................................................................. 51

50.1故障描述 ....................................................................... 51 50.2故障原因 ....................................................................... 51 50.3故障处理 ....................................................................... 51 51润滑脂警告故障 ..................................................................... 51

51.1故障描述 ....................................................................... 51 51.2故障原因 ....................................................................... 52 51.3故障处理 ....................................................................... 52 52液压油位低故障 ..................................................................... 52

52.1故障描述 ....................................................................... 52 52.2故障原因 ....................................................................... 52

14 / 53

52.3故障处理 ....................................................................... 52 53叶轮锁定故障 ........................................................................ 53

53.1故障描述 ....................................................................... 53 53.2故障原因: ................................................................... 53 53.3故障处理: ................................................................... 53

1.变频器准备反馈丢失

一、故障描述

故障名称:error_converter_not_rdy_on 故障代码:035001 二、触发条件

当主控制器检测到:1、风机启动过程中,如果变流器没有加热请求并且主控制PLC向verteco变频系统发出启动使能信号后,延时20s后主控制PLC没有收到变流器发出的预备启动信号,风机立即报此故障;2、风机在运行过程中主控制PLC没有收到变流器发出的预备启动信号,风机立即报此故障。叶片以4°/s变桨到86°,风机执行正常停机。

15 / 53

三、故障原因分析

风机启动过程中,如果变流器没有加热请求并且主控制器PLC向Verteco变频系统发出启动使能信号后,延时20s后主控制器PLC没有收到变流器发出的预备启动信号,风机立即报此故障;

风机在运行过程中,主控制器PLC在40ms内没有检测到Verteco变频系统发出的准备运行信号,风机立即报此故障; 四、故障处理方法

登陆风机监控界面,检查风机故障停机数据,确认故障原因; 检查并网断路器1Q1、防雷模块辅助触点接触是否良好,必要时更换。

2.电网电压高

一、故障描述

故障名称:error_grid_voltage_limit_max 故障代码:100101 二、触发条件

当主控制器检测到:如果电网三相电压中任意一相的电压持续1s高于438V ,风机报此故障。叶片以6°/s变桨到86°,风机执行快速停机。 三、故障原因分析

电网相电压出现升高或降低; 变流器内部网侧滤波器损坏; 测量模块KL3403损坏; 电压互感器损坏。 四、故障处理方法

如果全场机组都报这个故障,那就是电网原因; 电网测量模块KL3403损坏较多,则需要更换; 检查网侧滤波电容,如果损坏则需要更换;

如果以上原因都不是,检查电压互感器是否损坏,如果损坏则需要更换。

3.电网电压低

一、故障描述

故障名称:error_grid_voltage_limit_min

16 / 53

搜索更多关于: 金风1500kW风机常见故障处理手册 的文档
  • 收藏
  • 违规举报
  • 版权认领
下载文档10.00 元 加入VIP免费下载
推荐下载
本文作者:...

共分享92篇相关文档

文档简介:

42.1故障描述 ....................................................................... 42 40.2故障原因 ....................................................................... 42 42.3故障处理 ....................................................................... 42 43变桨安全链 ............................................................................ 43 43.1故障描述 .........................................

× 游客快捷下载通道(下载后可以自由复制和排版)
单篇付费下载
限时特价:10 元/份 原价:20元
VIP包月下载
特价:29 元/月 原价:99元
低至 0.3 元/份 每月下载150
全站内容免费自由复制
VIP包月下载
特价:29 元/月 原价:99元
低至 0.3 元/份 每月下载150
全站内容免费自由复制
注:下载文档有可能“只有目录或者内容不全”等情况,请下载之前注意辨别,如果您已付费且无法下载或内容有问题,请联系我们协助你处理。
微信:fanwen365 QQ:370150219
Copyright © 云题海 All Rights Reserved. 苏ICP备16052595号-3 网站地图 客服QQ:370150219 邮箱:370150219@qq.com