当前位置:首页 > 柱包钢法加固计算书范例
柱包钢法加固计算书范例
比较改造后标高4.200~8.400加固柱内力信息,取内力 N=2152.07kN, M=180.5kN·m
基本资料:b×h=500×500 C25:fc?11.9 As/?As?91mm12
lo?1.25h?1.25?4200?5250mm
计算:
?s??s/=40mm, ho?h??s
M180.5?106 eo===83.87mm
N2152.07?103ea=20mm或
h500??16.67mm,取ea=20mm 3030ei?eo?ea=83.87+20=103.87mm
lon?5250/500=10.08
.?5应考虑??15,?2?1.0
?1?0.5fcA0.5?11.9?500?500??0.69 N2152.07?103??1?l1(o)2?1?2?1??10.082?0.69?1?1.22 eh103.871400?1400i460ho1103.87=126.91<0.3ho=138 ?ei=1.22×
e??ei?h??s=126.91+250-40=336.91mm 2按对称配筋考虑,计算Nb
11.9×500×0.550×460=1505.35kN< N=2152.07kN,属Nb=?1fcb?bho=1.0×于小偏心受压
等等--------------------------------------以上可以选用世纪旗云计算
采用外包型钢加固法,选角钢L80×6,其基本参数为:
Ea?2.06?105N/mm2
?a=57.35cm4=0.5735mm4,Aa?9.40cm2?940mm2,由《混凝土结构加固
设
?so?(计规范》(GB50367-2006)得
0.8ho10.8?460?1)Eso?cu?(?1)?2.0?105?0.0033?100.64x319.31 0.8ho0.8?490?a?(?1)Ea?cu?(?1)?2.06?105?0.0033?154.75x319.31《混凝土结构加固设计规范》(GB50367-2006)P48式(8.2.2-2)
/////Aso(ho??so)+?soAso(?so??a)??afa/Aa右边=?1fcobx(ho?)?fyo(ho??a)
x2=1.0×11.9×500×319.31×(460-319.31/2)+300×911×(460-40)+100.64×911×(40-10)+0.9×210×2×940×(460-10)=848.05 kN·m >Ne=725.05 kN·m
所以可以选用角钢L80×6加固。